Sensores de Temperatura de la Serie STE-1400


STE-1400 Series 10,000 ohm, Type III thermistor, temperature sensors are available in different housings for surface, duct, duct averaging, immersion, strap-on, and outside air applications. All probes are constructed to provide good heat transfer and fast response. The averaging sensors are available in both plenum-rated cable or with a copper probe.

Rociadores


Sprinklers are installed according to the requested specifications for each specific case. All of them have UL/FM seals.
There are many types of sprinklers: Mounted, hanging, for the walls, hidden or specialized for storage. Of fast or standard response, for a specific temperature range and K factor requested.
Termination painted bronze, chrome or white with embellishing ring.

Bocas de incendio equipadas


The equipped fire hydrants are composed of a red metal enclosure with a glass door, a 25mm or 45mm globe valve, one or two hose sections, a kit of Storz fittings, and a multi-task or direct jet pointer.

Tubería Hierro Negro


The piping is made of Black Iron cell 20, using a grooved by cold embossing system, with grooved type UL/FM parts and accessories.
The threaded pipes, are made of Black Iron cell 40 with threaded parts of equivalent properties, according to NFPA 13.
The entire piping is painted with an anti-oxide base and a vermillion paint or a color of the client’s choice.

Sensor Térmico analógico direccionable

The thermal detector has an open case that allows air to enter, for optimal contact between the temperature sensor and the environment.

A measure of temperature is transmitted as an output voltage proportional to the air temperature. The analog signal is then processed and digitally transmitted to the Fire Control Panel.

Válvulas de Esfera Lineales

img48

VEB-43 (formerly VEP-45) series, two-way and  VEB-46 (formerly VEP-436) series, three-way NPT, ball valves are designed for the control of hot or chilled water in HVAC applications. Valves range in size from 1/2 to 3 inches feature an optimizing insert, which reduces the Cv and characterizes the ball opening for equal percentage flow characteristics. These valves include a field-repairable blowout- proof stem and leak-proof shut-of. The reduced torque seals and O-rings eliminate the need for high torque actuators and actuators require only low torque of the MEP-4000 series valves for all sizes. The standard connection is NPT optionally have to weld or BSP. It sizes ½” to 2”and has several Cv for each gauge, according to the model of the insert. The actuators may be modulating or floating.

Detector de Dióxido de Carbono (CO2) Serie SAE-1000

img70

These CO2 detectors sense and transmit carbon dioxide levels, for use in closed rooms occupied by people to ensure indoor adequate air quality while minimizing the energy costs of conditioning outside air.

It uses a NDIR (Non-Dispersive Infrared) sensor, which includes a microprocessor that adjusts the measure related to daily and historical trends. Output signal: 4 – 20 mA or 0 – 5 VDC proportional to the measured and adjusted value.

Detector de Monóxido de Carbono (CO) Serie SAE-1100

img71

These CO detectors sense and transmit carbon monoxide levels, for use in any industrial or commercial indoor environ­ment where accurate CO detection is required, i.e. parking.

Such information is crucial to demand controlled ventilation that ensures adequate indoor air quality while minimizing the energy costs of conditioning outside air. Uses an electrochemical sensor, Output signal: 4 – 20 mA, 0 – 5 VDC or 0 a 10 VDC proportional to the measured value.

Sensor de humo fotoeléctrico analógico direccionable

The slim-designed photoelectric analog addressable smoke sensor, transmits its address and analog values from the sensor’s chamber  to the Fire Control Panel for them to be analyzed. Inside of the sensor’s chamber there is a light pulse emitting LED and a photodiode. When smoke enters the chamber, the light pulse from the LED is diffused, and this is detected by the photodiode.

The sensor  has a red LED, that flashes briefly when the device is sending information, and turns constantly on if the device indicates an alarm.

The Fire Panel also registers the type of detector on the given address, so if the type of head is changed without it being reprogrammed,  an alarm will sound.

  • Saves the address on the sensor’s base.
  • Sets the address on a plastic card (XPert).
  • Provides its status using a two-colored LED.
  • Smoke is detected via infrared.
  • Transmits a constant communication.

Avisadores Manuales (pulsadores)

img75

The manual stations series includes fire alarm initialization devices, UL approved, which can connect together with other multiplex devices by the expansion module.

They are usually installed near the exit zone of a building, like doors and leaders, allowing people evacuation when a fire alarm is activated.

Anemómetros

img32

The anemometer is a weather anemograph or device used for weather forecasting and , specifically , to measure wind speed. It is also one of the basic flight instruments flight heavier -than-air aircraft.

In meteorology , it is mainly used cup anemometers or reel kind of tiny windmill blades with three cups on which the wind acts ; the number of turns can be read directly on a counter or registered on a strip of paper ( anemogram ) , in which case the device is called anemograph . Although there are also electronic type .

To measure the sudden changes in wind speed , especially in the turbulence , is resorted to anemometer filament , consisting of a platinum or nickel electrically heated : wind action has the effect of cooling it and do so vary their resistance ; therefore, the current flowing through the wire is proportional to the wind speed.

Sensores de Nivel

img34

It is an electronic device that measures the height of the material, usually liquid , in a tank or other container.
Integral control processes in many industries, level measurement sensors fall into two main types. Sensors measuring point level is used to mark a height of a liquid in a certain preset level . Generally, this type of sensor functions as an alarm , indicating an over filled when the particular level has been acquired, or the contrary, a low level alarm . Continuous level sensors are more sophisticated and can track the level of an entire system. These measure the fluid level within a specified range , rather than at a single point , producing an analog output that is directly correlated to the level in the vessel . To create a management system level , the output signal is related to a process control loop and a visual indicator.

Soft-starters Santerno

img67

This is the response for the soft start and stop of 220 to 15000 VAC motors.

Compact dimensions and prices
• 3 Adjustments: Initial start voltage, Start ramp time, Soft stop ramp time
• 6 Indications: No control power, Ready, Starter tripped, motor not running, Motor running at full speed, Motor starting or stopping
• 3 Alarms: Power circuit, Supply frequency, Communication failure
• 2 digital inputs: Start, Stop
• 1 Output relay: Main contactor relay
• Local reset

• Serial communication RS485; MODBUS RTU protocols

• Standard approvals: UL / CE

Variador de frecuencia Sinus Santerno

img64

• One product, 3 functions:
– For general applications, vector modulation IFD software
– For heavy torque performance, sensorless vector control VTC software
– For specific lift applications, vector modulation LIFT software
• Integrated filters on the full range in compliance with EN61800-3 2nd ed. about RFI emission limits
• Input contactor not necessary (doc. IEC 22G/109/NP draft of IEC61800-5 Safety requirements)
• Reduced dimensions up to 50%
• Intelligent cooling system
• Integrated braking chopper up to S30
• accepts over load 200% max torque for 5 seconds
• PID regulator
• 8 programmable inputs; 4 programmable analog inputs 0-10Vdc, 0(4)-20mA
• Serial communication RS485 with MODBUS RTU protocol

Sirenas

img22

Electronic Horns: indoor, outdoor, strobes, mixed, speakers.

The fire alarm siren is designed for use on the exterior of buildings, in order to
warn the outsiders detection of a home fire by the detection system and
fire alarm in the building. To this end, combines an acoustic signal and an indication
intermittent light. For its activation is only required to supply this voltage.
The fire siren is suitable for outdoor use. If you intend to use in an area
closed, it must be remembered that this siren sound intensity could be higher than
auditory discomfort threshold.