Rociadores


Sprinklers are installed according to the requested specifications for each specific case. All of them have UL/FM seals.
There are many types of sprinklers: Mounted, hanging, for the walls, hidden or specialized for storage. Of fast or standard response, for a specific temperature range and K factor requested.
Termination painted bronze, chrome or white with embellishing ring.

Bocas de incendio equipadas


The equipped fire hydrants are composed of a red metal enclosure with a glass door, a 25mm or 45mm globe valve, one or two hose sections, a kit of Storz fittings, and a multi-task or direct jet pointer.

Tubería Hierro Negro


The piping is made of Black Iron cell 20, using a grooved by cold embossing system, with grooved type UL/FM parts and accessories.
The threaded pipes, are made of Black Iron cell 40 with threaded parts of equivalent properties, according to NFPA 13.
The entire piping is painted with an anti-oxide base and a vermillion paint or a color of the client’s choice.

Sistema de supresión de incendios por agente limpio


The clean agent fire suspension system from Janus Fire Systems uses FM-200® or Novec™ 1230 as extinguishing agent.
FM‑200® is a colorless, non toxic gas, ideal for the protection of great value goods in zones that tend to be occupied by people, in places where the cleaning of other agents is problematic (other extinguishing agents characteristic residues), whenever there is a restricted place for the storage of a fire extinguishing agent, or whenever a non electric conductor agent is needed.
Novec 1230 is a transparent, colourless, and almost odorless liquid, ideal for the protection of great value goods in zones that tend to be occupied, in places where the cleaning of other agents is problematic (other extinguishing agents characteristic residues), whenever there is a restricted place for the storage of a fire extinguishing agent, or whenever a non electric conductor agent is needed.
The Novec 1230 (FK-5-1-12) liquid is composed by carbon, fluorine and oxygen. The primary extinguishing mechanism of the Novec 1230 liquid is the abortion of heat, with a secondary chemist input through the thermal decomposition of the Novec 1230 liquid by the flames. The Novec 1230 liquid does not leave any residues and it is safe to use in occupied areas.
The NOvec 1230 liquid is a highly fluorinated ketone, that does not contain either chlorine or bromine. Thus, the PAO (Potencial de Agotamiento del Ozono) of the Novec 1230 liquid is zero, so it does not affect the stratospheric ozone. The Novec 1230 liquid has a lifetime on the atmosphere of only 0.014 years.

Sensor Térmico analógico direccionable

The thermal detector has an open case that allows air to enter, for optimal contact between the temperature sensor and the environment.

A measure of temperature is transmitted as an output voltage proportional to the air temperature. The analog signal is then processed and digitally transmitted to the Fire Control Panel.

Sistema Integrado de Edificios

img91

This is a building management system that can be configured meeting specific and individual user’s requirements.

The BIS has a wide range of functions and features that make it work with Fire Detection as well as for the integration with all the electronic systems in high tech buildings.

Centrales E3

img6

The E3 Gamewell Series is a sophisticated fire protection system, also suitable to the customer’s needs.

Its modular design allows flexibility for almost any requirement, independent from the size.

FocalPoint

img72

This software controls and monitors in a graphic way every event in the fire system, in the panel and all its devices.

The FocalPoint Gateway is a powerful interface that provides the capacity to monitor multiple networks installed in remote locations. The gateway interfaces with the following standalone and network product lines via the panel´s RS-232 port

Sensor de humo fotoeléctrico analógico direccionable

The slim-designed photoelectric analog addressable smoke sensor, transmits its address and analog values from the sensor’s chamber  to the Fire Control Panel for them to be analyzed. Inside of the sensor’s chamber there is a light pulse emitting LED and a photodiode. When smoke enters the chamber, the light pulse from the LED is diffused, and this is detected by the photodiode.

The sensor  has a red LED, that flashes briefly when the device is sending information, and turns constantly on if the device indicates an alarm.

The Fire Panel also registers the type of detector on the given address, so if the type of head is changed without it being reprogrammed,  an alarm will sound.

  • Saves the address on the sensor’s base.
  • Sets the address on a plastic card (XPert).
  • Provides its status using a two-colored LED.
  • Smoke is detected via infrared.
  • Transmits a constant communication.

Avisadores Manuales (pulsadores)

img75

The manual stations series includes fire alarm initialization devices, UL approved, which can connect together with other multiplex devices by the expansion module.

They are usually installed near the exit zone of a building, like doors and leaders, allowing people evacuation when a fire alarm is activated.

Sirenas

img22

Electronic Horns: indoor, outdoor, strobes, mixed, speakers.

The fire alarm siren is designed for use on the exterior of buildings, in order to
warn the outsiders detection of a home fire by the detection system and
fire alarm in the building. To this end, combines an acoustic signal and an indication
intermittent light. For its activation is only required to supply this voltage.
The fire siren is suitable for outdoor use. If you intend to use in an area
closed, it must be remembered that this siren sound intensity could be higher than
auditory discomfort threshold.

Sistema de detección por aspiración FAAST


FAAST Smoke suction detectors have a fire detection with very early warning, highly accurate and wide communication capabilities to give maximum control into complex or critical environments.
– Detection as precise as 0.00046 %/ft obscuration.
– Multi-alarm levels and two sensitivity modes provide programming flexibility.
– Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement provides early notification of pipe network trouble conditions.
– Advanced detection algorithms reject common nuisance conditions.
– Patented particle separator and field-replaceable filter remove contaminants from the system reduces maintenance in even the harshest environments.
– The PipeIQ ™ program provides intuitive system design, configuration and monitoring, all in one.